ციკლონური გამწოვი
A cyclone dust collector spins chips out of the airstream before they reach the filter, so the filter stays clean, airflow holds up through a full shift, and waste drops into a wheeled bin instead of a bag you have to wrestle off a ring. This category holds 3 HOLZMANN RLE machines: the single-phase RLE1500 at 1900 m³/h, the RLE2200 at 2800 m³/h and the RLE3000 at 3200 m³/h with a 227 litre bin. All three combine a main inlet with three Ø100 mm branches and are supplied by quotation.
განახლდა
ნაპოვნი დანადგარები
-
HOLZMANN
HOLZMANN RLE1500 Cyclone Dust Collector – 1900 m³/h, 230V
RLE1500- Motor power
- 1.5 kW
- Voltage
- 230V
ფასი მოთხოვნით ფასის მოთხოვნა -
HOLZMANN
HOLZMANN RLE2200 Cyclone Dust Collector (2800 m³/h)
RLE2200- Motor power
- 2.2 kW
- Voltage
- 400V
ფასი მოთხოვნით ფასის მოთხოვნა -
HOLZMANN
HOLZMANN RLE3000 Cyclone Dust Collector (3200 m³/h)
RLE3000- Motor power
- 3 kW
- Voltage
- 400V
ფასი მოთხოვნით ფასის მოთხოვნა
Cyclone dust collector or bag collector?
A cyclone dust collector earns its extra cost in shops that extract all day. Because a cyclone drops the heavy chips into a bin before the air reaches the filter, the filter blinds far more slowly than on a bag collector, airflow stays closer to its rated figure late in the shift, and emptying means wheeling out a bin rather than unclamping a full sack. The RLE machines also run quieter than comparable bag units, at 71 dB(A) sound pressure on the RLE1500 and 74 dB(A) on the RLE2200 and RLE3000.
Sizing: match the main inlet to your trunk duct
Size a cyclone dust collector by its main inlet first. The RLE1500 takes a Ø150 mm main and moves 1900 m³/h at 2040 Pa – enough for one or two machines on short branches. The RLE2200 and RLE3000 step up to a Ø200 mm main, at 2800 m³/h and 2220 Pa and 3200 m³/h and 2470 Pa respectively, which is the size a fixed trunk line around a small production shop wants. All three add three Ø100 mm branches beside the main inlet, so machine hoods connect without a custom manifold.
Power supply decides more than airflow
Power supply splits this range in two. The RLE1500 is the only cyclone here that runs on 230 V / 50 Hz single-phase, from a 1500 W motor, so it is the choice for a workshop with no three-phase board. The RLE2200 (2200 W) and RLE3000 (3000 W) both require 400 V / 50 Hz three-phase. If three-phase is not installed, the RLE1500 is the ceiling of this category, and installing a board should be costed before comparing the larger machines.
Floor space, height and bin handling
Cyclones are tall and heavy, so check the building before the specification. The RLE1500 occupies 1280 x 790 mm and stands 1740 mm at 97 kg net; the RLE2200 occupies 1320 x 900 mm at 1840 mm and 136 kg; the RLE3000 shares that footprint but reaches 2190 mm and 153 kg. Add clearance above for filter service and, more importantly, room in front to roll the bin out: 110 l on the RLE1500, 151 l on the RLE2200 and 227 l on the RLE3000. Each machine also carries an 80 l bag on the fines side.
What you budget separately
Budget the ductwork with the cyclone dust collector. Trunk pipe in Ø150 or Ø200 mm, reducers to Ø100 mm branches, blast gates, flexible hose and clamps are separate items, as is the electrical installation and starter for a 400 V machine. Replacement filter elements and fines bags are consumables. If the shop is small enough that the run is short, a bag collector may be the cheaper honest answer; a cyclone pays back where the duct is fixed and the machine runs daily.
What the top of the range buys
Between the RLE1500 and the RLE3000 every number moves in the same direction: airflow from 1900 to 3200 m³/h, static pressure from 2040 to 2470 Pa, fan wheel from 365 to 400 mm, bin from 110 to 227 litres, and weight from 97 to 153 kg. The RLE3000 is the machine to specify when the duct run is long and the bin should be emptied once a day rather than three times.
როგორ ავირჩიოთ
- No three-phase supply in the building
- RLE1500 only - 1500 W on 230 V / 50 Hz. The RLE2200 and RLE3000 both require a 400 V three-phase board.
- Main trunk duct Ø150 mm
- RLE1500, which takes a Ø150 mm main inlet plus three Ø100 mm branches at 1900 m³/h and 2040 Pa.
- Main trunk duct Ø200 mm
- RLE2200 at 2800 m³/h or RLE3000 at 3200 m³/h; both take a Ø200 mm main inlet with three Ø100 mm branches.
- Ceiling height under 2 metres
- RLE1500 at 1740 mm or RLE2200 at 1840 mm. The RLE3000 stands 2190 mm and needs service clearance above that.
- How often you want to empty the bin
- 110 l on the RLE1500, 151 l on the RLE2200, 227 l on the RLE3000 - the 227 l bin is the reason most heavy users move up.
- Long duct run with several bends
- Choose on static pressure: 2470 Pa on the RLE3000, 2220 Pa on the RLE2200, 2040 Pa on the RLE1500.
- Noise in a shared workshop
- 71 dB(A) sound pressure on the RLE1500 and 74 dB(A) on the RLE2200 and RLE3000 - quieter than large bag collectors of similar output.